Conventional Systems

Explore our range of conventional systems, a reliable and economical solution for fire protection in small and medium-sized facilities. We offer panels, modules and fire detectors from leading brands such as Honeywell, Notifier and Morley. Our conventional systems guarantee precise and accessible protection, ideal for projects that require simplicity and efficiency.

-0.5% extra

On orders

≥500€ y <1000€

-0.8% extra

On orders

≥1000€ y <2000€

-1% extra

For orders

more than 2000€

INCREMENTAL DISCOUNTS

FASTER AND CHEAPER SHOPPING ON THE WEB

INCREMENTAL DISCOUNTS

FASTER AND CHEAPER SHOPPING ON THE WEB

Sort By
arrow-circle-down
columns
Morley Conventional Control Panel 4 ZONES VSN4-LT
Morley Conventional Fire Station with 4 zones.
Central CO Morley 2 ZONES VSN-PARK2
Morley 2/4 zone CO carbon monoxide detection station.
Morley Conventional Control Panel 8 ZONES VSN8-LT
Morley Conventional Fire Station with 8 zones.
Extinction Central Notifier RP1R-SUPRA
Notifier Fire detection and extinguishing center with 4.3 TFT touch screen.
Central CO2 Notifier PARK2000
1-zone carbon monoxide detection center expandable to 2 zones. Compact cabin that includes 1 Control Module, 1 P-100 Module, Power Supply and input for 24 Vdc emergency voltage.
Morley Fire Extinguishing Station VSN-RP1R-PLUS2
Morley Siren CWSO-RR-W1
EN54/3 Siren with IP65 High Base, Acoustic Warning Device for Fire Alarm.
Morley HSR-INT24 Siren
Conventional Morley Indoor Fire Siren Optical-Acoustic. Red color.
Morley HSR-E24 Outdoor Siren
Conventional Morley Outdoor Fire Siren Optical-acoustic. Red color.
Siren Notifier CWSS-RW-S5
Optical-acoustic siren with Standard Base. Classes C and W. Optical-acoustic warning device for Fire Alarm according to EN54/23 and EN54/3. Suitable for both Wall and Ceiling Mounting. It has 32 selectable alarm tones including a bell tone. High-performance LED Flash Provides omnidirectional light coverage. Synchronization is automatic. Complies with CPR construction standards, EN54/3 + EN54/23 C/W product categories, and RoHS and WEEE environmental standards. It is not suitable for outdoors or humid environments. In these cases, the optional Bases and Accessories CWR, PS189, PS188 must be used. Using the High Base reduces the dB output by about 4 dB on average. CWR Accessories Pack of 5 Red High Bases IP65 PS188 Pack of 5 O-rings for IP65 Base PS189 Pack of 5 gaskets for IP66 Base
Morley VSN-4REL Module
Card of 4 Programmable NO/NC Relays for NFS-SUPRA and RP1R-SUPRA Conventional Control Panels. Each Relay can be configured independently and linked to the 12 configurable trigger matrices. It is installed inside the Central. VSN-232 is required.
OSI-10 Notifier Receiver
OSID linear barrier receiver with 7° detection range up to 150m range powered at 24Vdc. Requires OSE-SPW Emitter (not included).
Morley ECO1003ABL A Optical Detector
Morley ECO1000 Series Conventional Optical Smoke Detector with flashing.
Morley ECO1004TABL A Thermal Detector
Conventional high temperature detector (78ºC). with led. for Base E1000B or E1000BR (ECO1000 Series), NOT INCLUDED. Dimensions with Base: 102 mm diameter, 50 mm high. Consumption 55 µA in standby, 70 mA in Alarm.
Morley Conventional Control Panel 12 ZONES VSN12-LT
Morley Conventional Fire Station with 12 zones.
Notifier NFS12-Supra Conventional Central
Micro-Processed Conventional Central with 12 Notifier zones and Remote connection option with TG-IP1-SEC Module (not included).
Pack 10 Plastic Notifier PS230
Pack of 10 Flexible Replacement Plastics for the KAC Series Resettable Pushbuttons.
Morley ECO1005ABL A Thermovelocimetric Detector
Morley ECO1000 Series Conventional Thermovelocimetric Thermal Detector with flashing.
Conventional Central Notifier NFS8-SUPRA
Microprocessed fire detection center with 8 zones. Distinguishes between Detector or Push Button Alarm per zone. Up to 32 Series 800 Detectors per zone. It includes a 2-output power supply, supervised sirens, general alarm relay, general fault relay, general indicators (fire, fault, service, CPU failure, general disconnection, in test, siren circuit fault), digital input for reset Remote, configurable delays, fixed 24V auxiliary output, resettable 24 Vdc output and zone indicators (Alarm, fault, disconnection, Test). Optionally, it allows you to connect the following Modules: up to 3 VSN-4REL Programmable Relay Cards, a VSN-232 RS232 Card, a TG-IP1-SEC IP Ethernet Card and a UCIP/UCIP-GPRS IP/GPRS Communicator Card.
Morley Conventional Control Panel 2 ZONES VSN2-LT
Morley Conventional Fire Station with 2 zones.
Morley ECO1000B Base
Standard Base for Morley ECO1000 Series Detectors. White color. Dimensions Ø 102 mm.
Notifier Base B401R
Standard surface base with 470 Ohm current limiting resistor for Conventional Detectors of the 400, 600 and 800 Series. It has automatic locking and connection terminals for Cable up to 2.5 mm2. Recommended for the connection of Sensors. the 400, 600 and 800 Series to the M710-CZR Module. Material PC/ABS Color Ivory Weight approx. 70 g Dimensions Ø: 102 mm H: 19 mm
OSE-SPW Notifier Issuer
Standard OSID linear barrier transmitter powered at 24Vdc. Requires OSI-10 Receiver (not included).
Notifier Detector SD-851E A
Conventional Optical Smoke Detector. Recommended for slow-evolving fires, with visible smoke particles. Incorporates compensation algorithms. Mounted on Base B401
circle-notch
circle-notch