Analog Systems

Explore our selection of analogue fire protection systems, designed to offer a reliable and efficient solution. Among our featured products are optical and thermal detectors, which guarantee early and accurate detection of fires. These systems allow the exact location of an incident to be identified, ensuring a quick and efficient response.

As a trusted distributor, we work with leading brands in the sector such as Notifier or Morley to ensure that your projects have advanced and high quality technology, thus ensuring maximum protection and security.

-0.5% extra

On orders

≥500€ y <1000€

-0.8% extra

On orders

≥1000€ y <2000€

-1% extra

For orders

more than 2000€

INCREMENTAL DISCOUNTS

FASTER AND CHEAPER SHOPPING ON THE WEB

INCREMENTAL DISCOUNTS

FASTER AND CHEAPER SHOPPING ON THE WEB

Sort By
arrow-circle-down
columns
M701E Notifier Module
Addressable Control Module for the activation of signaling systems, doors, fire doors, solenoids, etc. It has 1 configurable output circuit, using a microswitch, as a supervised output with EOL or in Relay form with voltage-free contacts. It incorporates a Loop short-circuit isolator circuit, LEDs for indicating the status of the module, a decadic address selector (01-159) and a DIN rail anchoring system. Allows surface mounting with M200SMB or SMB6-V0 Box. Compatible with OPAL 159+159 and Clip 99+99 Protocols.
Notifier Card 020-478
RS232 Serial Notifier Communication Card, opto-isolated for ID3000 Series Control Panels.
Notifier Card 020-588
Standard Card with 2 addressable Analog Notifier Loops for ID3000 Series Control Panels.
Analog Central Notifier ID60 002-456-001
ID60 1-Loop non-expandable analog central Notifier compatible with NFX Series Detectors.
Morley SMK400AP-IV Tube Socket
Socket for Tube up to 22mm for Base B501AP-IV not included. Ivory color
Notifier Card 020-549
Card with 2 addressable Analog Notifier Loops with built-in microprocessor for ID3000 Series Control Panels.
Notifier NRXI-GATE Gateway
Gateway compatible with Notifier Control Panels for the use of the Agile Radio System. Requires Base B501AP.
Notifier Pushbutton NRX-WCP
Waterproof Manual Alarm Call Point Via Radio Agile Notifier with mesh technology. Includes 4 CR123A batteries.
Morley push button M5A-RP06FF-K013-41
Morley Resettable Addressable Alarm Push Button with Isolator.
Thermovelocimetric Detector Notifier NFXI-TDIFF
Thermovelocimetric Thermal Detector with built-in Notifier Isolator. White color.
USB Notifier Device NRX-USB-Pro
USB Dongle with perpetual License. Connection to a PC through a USB port. Required to configure Agile Via Radio Detectors using the Agile IQ Notifier Software.
Flash Notifier WST-PC-I02
Transparent addressable flash and built-in isolator. Max consumption: 3.5mA. Strobe Flash Frequency: 1Hz. It connects to power directly from the Loop, occupying an address from 0 to 159 of the Control Module.
Support for Notifier Module M200E-DIN
Support for mounting a single M7xx or MI-Dxxx Series Standard Module, directly onto a Standard DIN rail section.
Source Notifier 020-579
Notifier 4.5 or 7A Power Supply for ID3000 Series Control Panels.
Notifier Base B501RF-RR
Standard red surface base for Analog Detectors of the NRX Series Via Radio Notifier, equipped with anti-extraction magnet. Red color.
Notifier Base B501AP
Standard surface base for NFX Notifier Series Detectors. White color.
Notifier Base B501RF
Base compatible with Agile Notifier Radio Detectors equipped with anti-extraction magnet. White color.
Morley B501AP-IV Base
Morley Standard Base for Analog Detectors. Ivory color.
Optical Detector Notifier NFXI-VIEW
White Optical Smoke Detector with IR Camera. Analog Detection with AWACS algorithms. Ideal for protecting high-value risks and where ultra-rapid smoke detection is required or in hyperventilated rooms. It incorporates manual and automatic test functions and decade addressing (01-159). It has two LEDs for Alarm indication and output for Remote Indicator. Only compatible with ID60, ID3000, PEARL Control Panels. Requires Base B-501AP.
Morley POL-200-TS Tool
Morley portable diagnostic and maintenance tool for Analog Loop with touch screen.
Source Notifier 020-648
Notifier 3A Power Supply for ID3000 Series Control Panels.
NFXI-MM10 module
Addressable Monitor Module with OPAL Protocol with 10 input circuits for the supervision of Alarm initiation equipment or technical signals that have Voltage-free Contact. Includes short circuit isolator. Allows the Connection of Devices in open or closed loop (with closed loop, the number of inputs is limited to 5). It connects directly to the Communications Loop and is compatible with all Notifier analog panels. It has microswitches for decade addressing (1-159) and tricolor LED indicators controlled by the panel. Compatible with OPAL 159+159 and Clip 99+99 Protocols. in Clip Protocol it occupies 10 consecutive Module addresses in the Loop. In OPAL Protocol it only occupies 1 address and subaddresses to complete the remaining addresses. For correct operation, requires Surface Mount Metal Box 002-439.
DNRE Notifier Box
Analysis box for Venturi effect duct detector
Notifier NRX-TDIFF Thermovelocimetric Detector
Agile Notifier Radio Thermovelocimetric Thermal Detector with mesh technology. Includes 4 CR123A batteries. Requires Base B501RF.